speedguide.net  

Port 44818 Details


known port assignments and vulnerabilities
threat/application/port search:
 search
Port(s) Protocol Service Details Source
44818 tcp,udp ethernetip Rockwell Encapsulation

Cognex In-Signt (IANA official) uses these ports:
68 udp - DHCP In-Signt vision system only
502 tcp - Modbus
1069 tcp/udp - In-Sight
1070 tcp - machine status data
2222 udp - Ethernet IP
5753 tcp - audit message server
44818 tcp/udp - Ethernet IP
51069 tcp - In-Sight secure

IANA registered for EtherNet/IP messaging


Cisco IOS is vulnerable to a denial of service, caused by an error within the Common Industrial Protocol (CIP) feature when processing malicious packets. By sending specially-crafted IPv4 packets destined to TCP port 44818, a remote attacker could exploit this vulnerability to cause the device to reload.
References: [CVE-2015-0649], [XFDB-101804]

Rockwell Automation ControlLogix is vulnerable to a denial of service, caused by the improper validation of input being sent to the buffer. By sending a specially-crafted CIP message to TCP and UDP ports 2222 and 44818, a remote attacker could exploit this vulnerability to cause the CPU to stop logic execution and enter a denial of service.
References: [XFDB-81235]

Rockwell Automation RSLinx Classic Versions 4.00.01 and prior. This vulnerability may allow a remote threat actor to intentionally send a malformed CIP packet to Port 44818, causing the software application to stop responding and crash. This vulnerability also has the potential to exploit a buffer overflow condition, which may allow the threat actor to remotely execute arbitrary code.
References: [CVE-2018-14829]

Rockwell Automation RSLinx Classic Versions 4.00.01 and prior. A remote, unauthenticated threat actor may intentionally send specially crafted Ethernet/IP packets to Port 44818, causing the software application to stop responding and crash. The user must restart the software to regain functionality.
References: [CVE-2018-14827]

Rockwell Automation RSLinx Classic Versions 4.00.01 and prior. This vulnerability may allow a remote, unauthenticated threat actor to intentionally send a malformed CIP packet to Port 44818, causing the RSLinx Classic application to terminate. The user will need to manually restart the software to regain functionality.
References: [CVE-2018-14821]

Tec4Data SmartCooler is vulnerable to a denial of service, caused by missing authentication for a critical function. By sending a specially crafted CIP packet to Port 44818, a remote attacker could exploit this vulnerability to cause a denial of service.
References: [CVE-2018-14796], [XFDB-150211]
SG
44818 tcp,udp rockwell-encap Rockwell Encapsulation SANS
44818 tcp EtherNet-IP-2 "EtherNet/IP messaging IANA
44818 tcp,udp EtherNet/IP-2 EtherNet/IP messaging IANA
44818 udp EtherNet-IP-2 "EtherNet/IP messaging IANA
5 records found

Related ports: 1069  2222  

News Glossary of Terms FAQs Cool Links SpeedGuide Teams SG Premium Services SG Gear Store
Registry Tweaks Broadband Tools Downloads/Patches Broadband Hardware SG Ports Database Security Default Passwords User Stories
Broadband Security Editorials General User Articles Quick Reference
Broadband Forums General Discussions
Advertising Awards Link to us Server Statistics Helping SG About